Esco Isoclean Pharmacy Compounding Aseptic Containment Isolator (Recirculating), provides a safe and clean environment for compounding of hazardous, sterile drug preparations in compliance with USP 797* criteria.
Barrier isolation system provides inherently superior sterility compared to open front clean air devices such as laminar flow clean benches and Class II biological safety cabinets. USP797 guidelines specify that isolators may be situated in an area subject to less severe environmental controls compared with open front clean air devices.
When used as part of a system that includes operator aseptic technique training, process validation, expiration setting and product quality maintenance after the CSP leaves the pharmacy, isolators are an effective solution especially for lower-volume pharmacies.. They reduce operating and renovation costs, take up less space, and are easier to maintain.
The Isoclean Compounding Aseptic Containment Isolator (Recirculating) is suitable for work involving hazardous materials, antineoplastic, or cytotoxic compounding applications. The work zone and pass-thru interchange are under negative pressure to the room in order to maintain operator protection in case of a breach in the barrier isolation system.
* United States Pharmacopoeia (USP), Chapter 797(1), enacted January 1, 2004, presents the first enforceable standards for sterile compounding. Following years of patient safety recommendations and professional guidelines, the intent of USP 797 is to set forth the procedural and practical requirements for safe compounding of sterile preparations. The Chapter's requirements are applicable in all practice settings where sterile preparations are compounded.
Key Benefits:
ISO Class 3 workzone
Superior operator protection
Fast purging time
Motorized height stand
Compliant to USP 797

| Model No. | External Dimensions (mm) |
Internal Dimensions (mm) |
Airflow Velocity (Inflow) |
Airflow Velocity (Downflow) |
Electrical |
| HPI-4N2 | 55 (fpm) | 110-120V,AC, 60Hz,1ø | |||
| HPI-6N2 | 55(fpm) | 110-120V,AC, 60Hz,1ø |

| STANDARDS COMPLIANCE | CABINET PERFORMANCE | AIR QUALITY | FILTRATION | ELECTRICAL SAFETY |
| CETA CAG-001-2005, USA CETA CAG-002-2006, USA USP CHAPTER 797, USA | ISO 14644.1, Class 3, Worldwide JIS B9920, Class 3, Japan JIS BS5295, Class 3, Japan US Fed Std 209E, Class 1 USA | EN-1822, Europe IEST-RP-CC001.3, USA IEST-RP-CC007, USA IEST-RP-CC034.1, USA | UL-61010-1, USA CAN/CSA-22.2, No.61010-1 EN 61010-1, Europe IEC 61010-1, Worldwide |